| Safety boots and shoes | SANS 20345 (ISO 20345) | 200 J toe cap. SB basic; S1 adds closed heel, antistatic and energy-absorbing heel; S1P adds midsole penetration resistance; S2 water-resistant upper; S3 S2 plus midsole and cleated sole. SRA/SRB/SRC slip resistance. | Typically 6–12 months in heavy use. Replace when the sole is worn smooth, the toe cap shows or is dented, or the upper splits. |
| Occupational shoes (no toe cap) | SANS 20347 (ISO 20347) | O1 to O3 classes, same properties as S1 to S3 without the toe cap. For hygiene or slip risk where nothing can fall on the feet. | As for safety footwear. |
| Safety gumboots | SANS 20345, S4 and S5 | S4: all-rubber or all-polymer, leakproof, with toe cap. S5: S4 plus penetration-resistant midsole and cleated sole. | When cracked, split or leaking, or the tread is worn. |
| Industrial hard hats | SANS 1397 / EN 397 | Shock absorption, penetration and flame resistance. Optional: −30 °C, +150 °C, 440 V a.c. electrical insulation, LD lateral deformation, MM molten metal. | Follow the manufacturer: shells commonly 3–5 years from manufacture, harness every 1–2 years. Immediately after a heavy blow, cracks, or chalky UV-faded plastic. |
| Bump caps | EN 812 | Protects against bumping into fixed objects only. Not for falling objects. | When damaged or as the manufacturer states. |
| Safety glasses, goggles, face shields | EN 166 / ISO 16321 | Optical class 1–3. Impact: S (12 m/s), F (45 m/s), B (120 m/s), A (190 m/s). Fields of use: 3 liquids, 4 large dust, 5 gas and fine dust, 8 short-circuit arc, 9 molten metal. K anti-scratch, N anti-fog. T = at extreme temperatures. | When lenses are scratched, pitted or cracked; often monthly on grinding work. |
| Welding helmets and filters | EN 175, EN 169, EN 379 | Shade numbers: typically 10–13 for MIG/MAG and stick welding, 9–12 for TIG at low current. EN 379 auto-darkening filters show light and dark shades. | Replace cover lenses when spattered; helmets when cracked. |
| Earplugs and earmuffs | EN 352-1, -2, -3 | SNR (single number rating) in dB, plus H, M and L values. Selected to bring the level at the ear to 70–80 dB(A). | Disposable plugs each shift; reusable plugs every 2–4 weeks; earmuff cushions about every 6 months. |
| Disposable dust masks | EN 149 | FFP1 (APF 4), FFP2 (APF 10), FFP3 (APF 20). NR: single shift; R: reusable; D: passed the dolomite clogging test. | NR masks after one shift, or sooner if damaged, wet or hard to breathe through. |
| Respirators and filters | EN 140, EN 136, EN 143, EN 14387, EN 12941/12942 | Half mask (EN 140), full-face (EN 136), particle filters P1–P3 (white), gas filters A brown, AX brown, B grey, E yellow, K green, Hg red, NO blue; classes 1–3 by capacity. Powered: TH1–TH3, TM1–TM3. | Gas filters on a change-out schedule; particle filters when breathing resistance rises; unopened filters by their expiry date. |
| Mechanical-risk gloves | EN 388 | Abrasion 1–4, coupe cut 1–5, tear 1–4, puncture 1–4, ISO 13997 cut A–F, P impact. X = not tested. | When worn through, cut, torn or stiff; disposables after each task. |
| Chemical and micro-organism gloves | EN ISO 374-1, EN ISO 374-5 | Type A (6 chemicals, 30 min), Type B (3 chemicals, 30 min), Type C (1 chemical, 10 min), with letter codes for the chemicals tested. EN 374-5: bacteria and fungi; VIRUS if virus-tested. | Per the breakthrough time for the chemical; discard after contamination. |
| Heat and welding gloves | EN 407, EN 12477 | EN 407 six digits for flame, contact, convective and radiant heat, small and large molten splashes. EN 12477 Type A (dexterity lower, more protection) or Type B (TIG, more dexterity). | When the leather hardens, burns through or seams open. |
| Electrical insulating gloves | EN 60903 / IEC 60903 | Class 00 (500 V a.c.), 0 (1 kV), 1 (7.5 kV), 2 (17 kV), 3 (26.5 kV), 4 (36 kV). Worn with leather over-gloves. | Air-test before each use; electrically retest every 6 months. |
| Arc-rated clothing | IEC 61482-2 | Arc rating as ATPV or EBT in cal/cm² (open arc test) or APC class 1 or 2 (box test). Must exceed the incident energy from the arc flash study. | When torn, contaminated with flammables or faded through; follow wash limits. |
| Flame-retardant clothing | EN ISO 11612, EN ISO 11611, EN ISO 14116 | EN ISO 11612 codes A (flame spread), B convective, C radiant, D molten aluminium, E molten iron, F contact heat. EN ISO 11611 class 1 or 2 for welding. | When the fabric thins, tears or after the wash cycles on the label. |
| High-visibility clothing | SANS / EN ISO 20471 | Class 1, 2 or 3 by the area of fluorescent background and retro-reflective tape; class 3 for road and rail work. | When colour fades, tape cracks or peels, or after the maximum washes on the label. |
| Rainwear | EN 343 | Water penetration class 1–4 and breathability class 1–4 (EN 343:2019). | When seams leak or the coating cracks. |
| Cold-weather clothing | EN 14058, EN 342 | EN 14058 for cool environments (down to −5 °C); EN 342 for cold, including cold stores and freezers. | When the insulation flattens or the shell tears. |
| Disposable coveralls | EN ISO 13982-1, EN 13034, EN 14126, EN 1073-2 | Type 5 dust, Type 6 light liquid splash, Type 4 spray-tight; EN 14126 infective agents; EN 1073-2 radioactive particles. | Single use: after each task or when torn. |
| Harnesses and fall arrest | EN 361, EN 355, EN 354, EN 360, EN 795 | EN 361 full-body harness, EN 355 energy absorber (up to 1.75 m extension), EN 354 lanyard (2 m maximum), EN 360 self-retracting lifeline, EN 795 anchors. The Construction Regulations, 2014 require a fall protection plan for work at height. | Pre-use check by the user; detailed inspection by a competent person at least every 6 months; withdraw after any fall; textiles per manufacturer (often 5–10 years). |
| Medical PPE | EN 455, EN 14683, EN 13795, EN 149 | Examination gloves (EN 455), surgical masks Type I, II, IIR (EN 14683), surgical gowns (EN 13795), FFP2/FFP3 for airborne infections. | Single use per patient or procedure. |